Alarm Bell
Contacts
- Allows
alarm bell connection to pressure controls for signaling if
unit fails on manual reset safety controls. (alarm bell is
not included but can be provided) |
√ |
√ |
√ |
√ |
√ |
√ |
|
Brine
Chilling
- Modified
cooler and controls for various brines/glycols/alcohols. |
√ |
√ |
n/a |
n/a |
n/a |
n/a |
|
Centrifugal
Condenser Fans
- For ducted
applications |
√ |
n/a |
√ |
n/a |
n/a |
√
(air-to-water) |
|
Chilled
Water Pump/Valve
-Includes
chilled water circulating pump, pump starter, and isolation
valve. Provides system pump for chilled water circulation-
saves field labor and material. This pump is interlocked
with the flow switch and “phased in” at the factory for
proper rotation. Back up pump and VFD also available. |
√ |
n/a |
√ |
n/a |
n/a |
√ |
|
Condenser
Water Pump/Valve
- Includes
condenser water circulating pump, pump starter, and
isolation valve. This pump is interlocked with the flow
switch and “phased in” at the factory for proper rotation.
Back up pump and VFD also available. |
n/a |
√ |
n/a |
√ |
n/a |
√ |
|
Complete
Unit Coating
- Your
choice of paint color or Heresite coating for compete unit.
Standard unit is painted/primed with neutral Continental
Gray finish. Sheet metal is powder-coated with Continental
Gray finish. |
√ |
√ |
√ |
√ |
√ |
√ |
|
Compressor
Circuit Breaker
- Both fused
and non-fused short circuit protection for each compressor,
further reducing chance of motor burnout. |
√ |
√ |
√ |
√ |
√ |
√ |
|
Compressor
Cycle
Counter/Hour
Meter |
√ |
√ |
√ |
√ |
√ |
√ |
|
Control
Transformer
- For
applications where a separate 115 V power source is not
available, a transformer can be installed and wired between
the line voltage power terminal block and the 115 V control
circuit. Transformer is fused, factory mounted and wired.
Also available for 24 V. |
√ |
√ |
√ |
√ |
√ |
√ |
|
Copper
Tube/Copper Fin Condenser Coil
|
√ |
n/a |
√ |
n/a |
n/a |
√
(air-to-water) |
|
Cu Ni
Evaporator |
√ |
√ |
n/a |
n/a |
n/a |
√
(air-to-water) |
|
Cu Ni
Condenser |
n/a |
√ |
n/a |
√ |
n/a |
√
(water-to-water) |
|
Desuperheater
- Provides
“free hot water” by recovering heat from super heated gas. |
√ |
√ |
√ |
√ |
√ |
√ |
|
Digital
Temperature Readout |
√ |
√ |
n/a |
n/a |
n/a |
√ |
|
Dual Unit
Kit
- Allows
operation of two or more units |
√ |
√ |
√ |
√ |
√ |
√ |
|
E-Coated
Condenser-
Coil is coated with E-Coating for protection against
elements. Minimal effect on heat transfer. |
√ |
n/a |
√ |
n/a |
n/a |
√
(air-to-water) |
|
Economizer/Free Cooling
– Chilled water economizer is available for all air cooled
systems. An outdoor water coil is part of the system and
produces chilled glycol in winter without operating the
compressor, saving energy. |
√ |
n/a |
√ |
n/a |
n/a |
n/a |
|
Flow Switch
-Mandatory for Continental warranty to be effective.
Provides protection from chiller freezing due to “no flow”
through chiller-evaporator. |
√ |
√ |
n/a |
n/a |
n/a |
√ |
|
Fused
Disconnect
– Located
alongside the control panel to meet/exceed NEC requirements. |
√ |
√ |
√ |
√ |
√ |
√ |
|
Heat
Recovery
– For
higher efficiency, heat recovery is available on all
equipment. |
√ |
√ |
√ |
√ |
√ |
√ |
|
Heresite
Coating
–
Available for copper/aluminum or copper/copper condenser
coils for extra protection against elements. |
√ |
n/a |
√ |
n/a |
n/a |
√
(air-to-water) |
|
High
Entering Water Process Cooling
- Secondary
plate heat exchanger with pump, factory mounted and
wired to protect compressor against burnouts due to high
water temperatures. |
√ |
√ |
n/a |
n/a |
n/a |
n/a |
|
High Return
Water Thermostat
- Factory
mounted thermostat senses high return water temperature at
start-up. Allows unit to run un-loaded instead of shutting
down due to high head pressure. |
√ |
√ |
n/a |
n/a |
n/a |
n/a |
|
Hot Gas
Bypass –
Provides
cooling at low loads. Includes HGBP valve and solenoid valve
on lead compressor. |
√ |
√ |
√ |
√ |
√ |
√ |
|
Indicating
Lights –
Three
indicating lights per circuit: Power On, High Pressure Fail,
No Flow/Freeze |
√ |
√ |
√ |
√ |
√ |
√ |
|
Low Ambient
Controls
-Standard
units have fan cycling and are good for 45°F ambient. a) For
Low Ambient to 0°F- a modulating solid state fan speed
controller and a single phase condenser motor(s) as well as
fan cycling. b) For Low Ambient to –20°F - head pressure
control valve in conjunction with oversized heated and
insulated receiver(s) and fan cycling. Receiver includes
pressure relief valve, heater tape and insulation. |
√ |
n/a |
√ |
n/a |
n/a |
n/a |
|
Low
Evaporator Pressure Freezestat
- Senses low
evaporator pressure and shuts down system after sixty second
time delay. Extra safety protection against low pressure due
to gas shortage or freeze conditions. |
√ |
√ |
n/a |
n/a |
n/a |
√ |
|
Low Speed
Condenser Fan Motors
- For lower
noise levels |
√ |
n/a |
√ |
n/a |
n/a |
√
(air-to-water) |
|
Micro-Processor Controller-
BACNet open protocol systems |
√ |
√ |
√ |
√ |
√ |
√ |
|
Potable/Ingredient Water at 34°F
- For
bakeries/produce or drinking water applications. |
√ |
√ |
√ |
n/a |
n/a |
n/a |
|
Power Supply
Monitor –Provides
Protection against phase loss, phase reversal, phase
imbalance, incorrect phase sequences and low line voltage. |
√ |
√ |
√ |
√ |
√ |
√ |
|
Pressure
Gauges
- Two-inch
diameter gauges are factory installed and piped to
compressor. High and low pressure for each refrigerant
circuit. |
√ |
√ |
√ |
√ |
√ |
√ |
|
Stainless
Steel Hardware
-For extra
protection against corrosion. |
√ |
√ |
√ |
√ |
√ |
√ |
|
Tank/Process
Pump – |